AT - Casing System

AT - Pipe Umbrella Support System

 

 

 

Field of application AT - Pipe Umbrella Support System

  • Tunneling in heterogeneous, soft, or subsidence-sensitive ground
  • Tunneling through fault zones
  • Unstable ground conditions at the working area
  • Shallow tunnels in urban areas


AT - Pipe Umbrella Support System - mode of action

  • Support of the tunnel wall in the region of the face
  • Distribution of loads in the longitudinal direction
  • Ground improvement ahead of the tunnel face by grouting
  • Reduction of subsidence due to ground improvement and load distribution
  • Drainage and ground support also by non-injected casing tubes


Standard structural properties AT - Pipe Umbrella Support System

  • AT - 76: 76,1 x 5,6
  • AT - 89: 88,9 x 6,3
  • AT - 114: 114,3 x 6,3
  • AT - 139: 139,7 x 8,0 bzw. 142,0 x 10,0
  • AT - 168: 168,0 x 12,5

Depending on project requirements and customer demands, the AT - Casing System can be adjusted by changing the structural properties.


Optionally, the AT - Pipe Umbrella Support System is also available in combination with a particular pipe connection.
This so-called "threaded nipple coupling" enables the extension of pipes without reducing the pipe’s strength in the section of the threads. Thereby, the total and constant load-bearing capacity of the casing pipes is warranted over the entire length of the pipe umbrella.

 

AT - Casing System

 




  1. Casing tube
  2. Single-use drill bit
  3. Impact shoe
  4. Impact ring
  5. Adapter with flushing valve


 

Injection Equipment

AT - RIA Rotary-Injection-Adapter

AT - Flow-Pressure Meter

AT - Mortar-Mixing pumps: M400

EASY / M400 NT

read more...read more...read more...